TM 9-2350-261-20-4
REPLACE AC POWER EXTENSION BOX A7 (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Equipment Condition
Maintenance Level
Engine stopped (see your -10)
Unit
Carrier blocked (see your -10)
Tools and Special Tools
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
Materials/Parts
Locknut (4)
Personnel Required
Power-Generation Equipment Repairer 52D10
REMOVAL
1.
Disconnect cable W8 (1) from connector J1 (2) on AC power extension box A7 (3).
2.
Remove four screws (4), washers (5), locknuts (6), and AC power extension box A7 (3) from mount (7). Discard
locknuts.