TM 9-2350-261-20-2
I N S T A LL
WARNING
Cooling fan is heavy and
can cause back injury if
handled improperly. Be
sure to use a hoist or helper
to install cooling fan.
7.
8.
9.
10.
11.
12.
Fill fan drive right angle gearbox (1) if
required (see your LO).
Install packing (2) and plug (3) on right
angle gearbox (1).
Install fan drive pulley (8) on fan assembly
(4) (page 8-41).
Attach sling and suitable lifting device of at
least 150 lbs (45 kg) capacity to fan assem-
bly. Lift fan assembly (4) and install on
power plant grill (5).
Install six screws (6) and washers (7).
Tighten screws to 292-336 lb-in
(33-38 Nm) torque. Use torque wrench and
socket wrench set.
If removed, instaIl new decal (9)
FOLLOW-THROUGH STEPS
1. Lower power plant grill (page 5-2).
END OF TASK
Change 4
8-45