TM 9-2350-261-20-2
REPAIR
4. Use dry
seal (1)
5. Apply a
cleaning solvent to remove five-piece
from radiator access door (2).
thin coat of adhesive sealant to bot-
tom surface of new five-piece seal (1). Apply
same sealant to seal area of radiator access
door (2).
INSTALL
6.
7.
8.
9.
Install new five-piece seal (1) on radiator ac-
cess door (2). Allow 20 minutes to dry.
Secure two fasteners (3) to radiator access
door (2) with four new rivets (4). Use rivet
tool.
Close radiator access door (2). Secure door to
radiator opening with two fasteners (3).
Secure radiator access panel (5) to power
plant compartment bulkhead with two clamps
(6) and thumbscrews (7).
FOLLOW-THROUGH STEPS
Install drivers power plant access panel
(page 24-25).
END OF TASK
8-26