TM 9-2350-261-20-1
I N S T A L L
3.
4.
5.
6.
7.
8.
9.
10.
Secure indicator (1) to bulkhead with two
screws (2), washers (3), and new
locknuts (4) .
Apply a thin coat of sealing compound to
threads of adapter (5).
Install adapter (5) in indicator (1).
Connect indicator hose (6) to adapter (5).
Install air cleaner cover (page 7-5).
Install air cleaner housing and element
(page 7-7).
Install air cleaner inlet hose (page 7-3).
Install drivers power plant access panel
(page 24-25).
WARNING
Loose clothing is dangerous
around moving belts and
pulleys. You could get bad-
ly hurt if your clothes get
caught in moving parts.
11. Start engine and set at 800 rpm
(see your -10).
12.
13.
14.
15.
Block air cleaner outlet opening with a piece
of cardboard. Check window in indicator. It
should be red.
Turn engine off, and remove cardboard.
Indicator should remain red.
Press reset button on indicator. Window
should turn green.
If indicator does not operate properly,
replace it.
FOLLOW-THROUGH STEPS
1. Engine stopped/shutdown (see your -10).
3. Close power plant front access door
(see your -10).
2. Install air cleaner outlet hose (page 7-3).
4. Raise trim vane (see your -10).
END OF TASK
7-10