TM 9-2350-261-20-1
R E P L A C E A I R B O X H E A T E R I G N I T I O N C O IL
INITIAL SETUP
Tools:
Equipment
General Mechanics Tool Kit (Item 30, App D)
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Personnel Required:
Battery ground lead disconnected (page 13-2)
Unit Mechanic
Trim vane lowered and power plant front
access door open (see your 10)
References:
See your -10
REMOVE
1. Disconnect circuit
high tension wire
406 and
(2) from
2. Remove
coil (3),
INSTALL
406A plug (1) and
3. Install ignition coil (3) and pad on mount (7).
ignition coil (3).
Secure with retainer (6), washer (5), and
screw (4).
(5), retainer (6),
screw (4), washer
and pad from mount (7).
4. Connect circuit 406 and
high tension wire (2) to
406A plug (1) and
coil (3).
FOLLOW-THROUGH STEPS
1. Close power plant front access door and raise
trim vane (see your -10).
2. Connect battery ground
page 13-2).
6-132
END OF TASK
Conditions: