TM 9-2350-261-20-1
1. Measure voltage between terminal 6B (1) on
circuit breaker and ground.
2. Does multimeter read less than 17 volts?
YES
1. Remove battery box cover.
2. Remove 6B pos (+) and 7B neg (-) terminal from
battery post.
3. Measure resistance between 6B pos (+) (1) terminal
from battery and circuit breaker.
4. Measure resistance between 7B neg (-) (2) terminal
from battery and circuit breaker.
5. Does multimeter read 0 ohms for either measure-
ment?
1. Replace circuit breaker
(page 44-2).
2. Verify no faults found.
1. Replace cable assembly
11647667 (page 44-6).
2. Verify no faults found.
3-234