TM 9-2350-261-20-1
1. Set BLACKOUT ENABLE switch to down position.
2. Set AC LIGHTS switch in upward position (see
TM 11-7010-256-12&P).
3. Measure resistance between terminal 2 (1) and ter-
minal 1 (2) of circuit breaker CB17 (3).
4. Does multimeter read 0 ohms?
GO TO NEXT PAGE
1. Replace circuit breakers
CB17 (page 40.1-33).
2. Verify no faults found.
Change 3
3-226.107