TM 9-2350-261-20-1
1. Remove master power harness circuit 10 plug (1)
from instrument panel circuit breaker (2).
2. Measure resistance between master power harness
circuit 15 plug (3) and circuit 10 plug (l).
3. Does multimeter read 0 ohms?
1. Install master power harness circuit 10 and 15
plugs.
2. Replace lighting control switch (page 11-9).
3. Verify no faults found.
1. Install front main harness
lighting control switch plug
on switch.
2. Repair master power
harness (page 14-3).
3. Verify no faults found.
3-74