TM 9-2350-261-10
WARNING
When power plant
door detent screw
is missing or does
n o t r u b a g a i n s t
closed position, power plant
door can open and take in water
during
water
operations.
Carrier can sink and personnel
can drown.
Do not attempt
water operations when detent
screw is missing or improperly
adjusted.
N O TE
If detent screw is missing or does
not rub against the handle,
notify- unit maintenance to have
screw
replaced/adjustedor
handle replaced.
13. Secure power plant door.
a. Rotate handle past detent
screw to vertical position
between screw and metal
stop.
14.
b. Check power plant door seals
for breaks, brittleness, cracks,
or poor seating.
From inside the drivers
compartment, push the combat
lock handle down to lock the
power plant door (page 2-151).
WARNING
Unsecured stow-
age/load can shift
o r
f a i l d u r i ng
c a r r i e r
motion.
Personnel can be
injured. Secure all
stowage/load to eliminate move-
ment regardless of carrier atti-
tude,
including
inverted
position.
Carrier can sink
and personnel can
drown when maxi-
mum load (weight
of personnel, fuel
and/or cargo) is
exceeded and/or not properly
distributed. Distribute weight of
cargo and/or personnel evenly
before entering water, per load
plan in Appendix F.
15. Stow carrier in accordance with
load plan (see Appendix F).
2-278