TM 9-2350-247-20-2
REPLACE FINAL DRIVE GAUGE ROD -- Continued
0328 00
INSTALLATION
NOTE
Due to failure of output shaft seal, final drive oil quantity must be increased. To measure
correct amount of oil, both final drive gauge rods must be modified as shown in WP 0326 00.
1.
Insert gauge rod (1) into final drive (2) and turn to the right to lock.
FOLLOW-THROUGH STEPS
1.
Install left or right center floor plate (WP 0394 00) or (WP 0395 00).
END OF TASK