TM 9-2350-247-20-2
REPLACE GENERATOR FIELD SWITCH -- Continued
0288 00
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
1.
Check circuit lead. Replace worn or cracked lead and damaged connector (WP 0294 00). Use multimeter to check
leads and generator field switch.
INSTALLATION
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
1.
If replacing plug and washer, coat threads on plug (4) with sealing compound. Install washer (5) and plug (4) on side of
switch (2).
2.
Coat threads of new switch (2) with sealing compound.
3.
Install new generator field switch (2) in tee (3).
4.
Connect circuit 1A and 1B lead plug (1) to generator field switch (2).
FOLLOW-THROUGH STEPS
1.
2.
Lower cab personnel seats (see your -10).
END OF TASK
Change 1