TM 9-2350-247-20-2
REPLACE BILGE PUMP CIRCUIT BREAKER
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Maintenance Level
References
See your -10
Unit
Equipment Condition
Tools and Special Tools
Engine stopped (see your -10)
General Mechanic's Tool Kit (WP 0541 00, Item 57)
Carrier blocked (see your -10)
Materials/Parts
Driver's seat raised (see your -10)
Lock nut (2)
Center seat raised (see your -10)
Personnel Required
Unit Mechanic
REMOVAL
NOTE
Circuits 450, 450A, and related circuit breaker are inactive.
1.
Disconnect circuit 450B (1) and 450C (2) leads from bilge pump circuit breaker (3).
2.
Remove two screws (4), lock nuts (5), and circuit breaker (3) from bulkhead. Discard lock nuts.