TM 9-2350-247-20-2
REPLACE GENERATOR REGULATOR MOUNT (M548A1) -- Continued
0250 00
2.
Align mounting plate (3) with generator regulator (4). Secure mounting plate (3) to generator regulator (4) with four
machine screws (6) and eight new lock washers (7).
3.
Align mounting plate (3) with four mounting bracket weld nuts (12). Secure mounting plate (3) to mounting bracket (5)
with four cap screws (1) and eight new lock washers (2).
FOLLOW-THROUGH STEPS
1.
Connect battery cable and power plant wiring harness to generator regulator (WP 0295 00).
2.
3.
4.
Start engine (see your -10).
5.
Check for proper operation of generator regulator.
6.
Stop engine (see your -10).
7.
Install top access cover and grilles (WP 0390 00).
END OF TASK
0250 00-3/4 blank