TM 9-2350-247-20-2
REPLACE 100 AMP GENERATOR (M548A1) -- Continued
0242 00
INSTALLATION
NOTE
Fill gaps between generator mounting lugs with shim washers before tightening screws and
nuts. This will prevent damage to generator.
1.
Place key (1) in generator shaft slot.
2.
Install sleeve bushing (2) and pulley (3) on generator (4) shaft. Secure with three washers (5) and screws (6). Torque
screws to 73-79 lb-in (8-9 Nm).
3.
Place generator (4) with pulley (3) installed, on generator mount (7). Secure with three cap screws (8) and new lock
nuts (9).
4.
Connect wiring harness (10) to generator (4).
FOLLOW-THROUGH STEPS
1.
2.
3.
4.
Start engine (see your -10).
5.
Check generator output for proper operation.
6.
Stop engine (see your -10).
7.
Install power plant rear access covers/door (see your -10).
END OF TASK