THIS WORK PACKAGE COVERS:
Start Engine with External Power (page 0015 00-1).
INITIAL SETUP:
Maintenance Level
Operator
Tools and Special Tools
Slave Cable
Source Carrier
Personnel Required
Driver (2)
Equipment Condition
Carrier unable to start under own power
START ENGINE WITH EXTERNAL POWER
CAUTION
Do not start carrier without batteries installed. Starting engine with outside power and no
batteries will damage voltage regulator.
1.
Position source carrier next to dead carrier so that slave cable can connect auxiliary power receptacles on both carriers.
Stop engine on source carrier.
2.
Make sure MASTER SWITCH is OFF on both carriers.
NOTE
Step 3 and Step 4 are for M548A1.
3.
Unscrew the cap from your auxialiary power receptacle.